Axis 7100 Installationsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 424
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
Safety First
Advanced Dicing Technologies Ltd.
vi
displayed if the Spindle Cover is opened while an Axis is
moving or when a bypass key is used. The Axes stop
immediately and the spindle keep moving mechanically.
The Spindle Interlock is automatically engaged while the
Dicer is initializing, and disengaged when initialization is
completed. In addition, the Spindle Interlock is disengaged
whenever the System is powered down. The Model 7100
cannot be powered down while the spindle is rotating.
During the Blade Change procedure, the Spindle Interlock
automatically disengages when the Spindle is turned off by
the System. At the end of the procedure, the Software reminds
the User to close the cover before clicking Finish. The Spindle
Interlock then re-engages automatically to protect the User
while the Dicer initializes. For more information about
changing the Blade, see
Chapter 7.
The Spindle Interlock can be locked and unlocked from the
Dicer screen in the Setup & Diagnostics workbook. Access
rights to this function can be restricted. For more information
about the Setup & Diagnostics workbook, see
Chapter 2. For
more information about access rights and Access Levels, see
Chapter 4.
Load/Unload Interlock (7100EUR only)
The Load/Unload Interlock prevents the Load/Unload Cover from
being opened while the Model 7100 is operating. The Interlock is only
disengaged when Workpieces are loaded or unloaded from the Cutting
Chuck.
Unlike the Spindle Interlock, the Load/Unload Interlock is
automatically engaged after initialization. It disengages only after the
User initiates the Load procedure. X, Y and Theta Axes are initialized
when the procedure is completed.
During the Load procedure, another message appears after the
Workpiece has been accepted by the Cutting Chuck, reminding the
User to close the Load/Unload Cover before continuing. (This enables
the User to leave the cover open in cases where the Workpiece needs to
be manually held in place by the User before it can be accepted by the
Chuck.) An error message appears if the Load/Unload Cover is not
closed within a reasonable time by the User.
Note: Once the Blade Change button is pressed, the Spindle Interlock is
unlocked and cover can be opened. The user has 20 seconds to open the
cover. If the cover has not been opened within 20 seconds, the interlock locks
back and can be bypassed by means of a key.
Seitenansicht 5
1 2 3 4 5 6 7 8 9 10 11 ... 423 424

Kommentare zu diesen Handbüchern

Keine Kommentare