Axis 7100 Installationsanleitung Seite 201

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 424
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 200
ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Kerf Checking
P/N 97100-9002-000-14 Ver 06/05
6.3-5
The distance between the red lines is the maximum Kerf width (Wmax in
Figure 6-25) and the distance between the green lines is the minimum Kerf
width (Wmin in Figure 6-25). The yellow line is the center of the Kerf.
The results of each Kerf Check are displayed in the FOV.
If the limits are exceeded, the System’s action depends on the option
specified in the Recover parameter, as follows:
Pause: An error is shown, and the automatic cutting process does not
resume. The User then decides whether to continue the cutting
procedure, change the Kerf Check parameters or cancel the cutting
process.
Ignore: No error is shown, and the automatic cutting process
continues.
Report: An error is shown, but the automatic cutting process
continues.
The results of a Kerf Check are also displayed in the Top View Area and
the Multiview-12.
Figure 6-25: Kerf Check Measurements
Seitenansicht 200