Recipe Parameters
Blade Parameters
Advanced Dicing Technologies Ltd.
A-22
Blade Parameters
Table A-7 lists the Blade parameters. Blade parameters are used to define
the permitted wear of the Blade.
Table A-7: Blade Parameters
Category Parameter Description
Blade
After Change
Treatment
Whether to perform Dressing, Override or neither
after a Blade Change.
Possible Values:
None (default), Override, Dressing
Blade Max Wear Rate
The maximum amount the Blade can wear down
within a specified cut length.
Possible Values:
min = 0, max = 100, Default = 0
Blade Min Exposure Left
The minimum exposure permitted before a Blade
stops cutting.
A value must be specified for this parameter and Min
Exposure Warn Delta OR Max Wear and Max Wear
Warn Delta.
Possible Values:
min = 0, max = 100, Default =.1
Blade
Min Exposure
Warn Delta
The minimum exposure on the Blade that triggers a
warning.
This parameter should be specified with Min
Exposure Left.
Possible Values:
min = 0, max = 100, Default =.1
Blade Warn Cut Length
The maximum cut length permitted before the Blade
must be changed.
Possible Values:
min = 0, max = 1E+06, Default = 1E+06