Recipe Parameters
Air Parameters
Advanced Dicing Technologies Ltd.
A-12
Appendix 3: Recipe Parameters
The Model 7100 software contains the parameters described in the
following sections. Parameters are listed alphabetically by category.
For information about how to specify parameters and adding parameters to
Recipes, see
Chapter 5.
Air Parameters
Table A-1 lists the Air parameter available in the Model 7100. This
parameter is used for the air puff feature employed by the System when
unloading Workpieces from the Cutting Chuck.
Note: When defining parameters in a Recipe (for example, Index), the User
can select a different unit of measurement for each parameter, including:
• millimeters
• inches
• mils
• centimeters
• meters
• microns
• degrees
• radians
The Possible Values provided for each parameter in this Appendix are
rendered in millimeters, unless otherwise specified.
Table A-1: Air Parameters
Category Parameter Description
Air
Stop Air After Air
Puff
Defines whether or not to stop the air puff after the
Unload Air Puff time has elapsed.
Possible Values:
Yes (Default); No
Air Unload Air Puff
The duration (in sec.) of the air puff used for releasing
Workpieces from the Cutting Chuck.
Possible Values:
min = 0, max = 100, Default = 2