ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Stopping System Operation
P/N 97100-9002-000-14 Ver 06/05
3.7-1
3.7 Stopping System Operation
System operation can be halted in different ways, depending on whether it
is operating in Auto mode or Manual mode:
• Emergency Stop, see section 3.7.1
• Stop/OFF Button, see section 3.7.2
• Pausing Process in Auto mode, see section 3.7.3
• Manual Stop, see section 3.7.4
Each way of halting System operation has a different effect on the System
and on the Workpiece currently being processed.
3.7.1 Emergency Stop
The Emergency Stop button on the System Front Panel is used to
immediately stop all System operation to avert potential harm to the User
or System.
When the Emergency Stop button is pressed, the Main Circuit Breaker is
turned off, cutting power to the System. All System operation comes to an
immediate halt. The Air Tank continues to supply air to the Spindle for a
short period of time in order to prevent damage to the Spindle.
To recover from an Emergency Stop, pull the plastic cover off the button,
pull the button outward, and then turn the Main Circuit Breaker back on.
3.7.2 STOP/OFF Button and Soft Stop Button
The operator can immediately stop any activity in order to prevent self-
injury or damaging the material. The system can be stopped
either by clicking the Stop icon on the screen, or by pressing the OFF
button on the control panel of the system (see also section 2.1.1.2 and
section 2.2.9).
Figure 3-6: Emergency Stop Button
Note: The STOP/OFF button is spring-loaded to always be ready in its "out"
position.
Kommentare zu diesen Handbüchern