ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Load Monitoring
P/N 97100-9002-000-14 Ver 06/05
8.1-5
To Access the Load Monitor Control Screen:
From the Load Monitor menu, click Control. The Control screen
appears.
The Load Monitor Control screen contains the following features:
Sampling Period: The frequency of load sampling. This value is pre-
set to sample every 100 msecs. It is recommended not to change this
value.
System Overload: The maximum load value that Model 7100 can
handle. If the load exceeds this value, the cutting stops. This value is
also used as the max value for the analog gauge.
Measure Baseline: Allows the User to check the baseline between
cuts if required.
Display Data as Net Load: Displays the Baseline on both graphs as
zero. This feature causes the Load Monitor to illustrate the Net Load of
the cut only.
Save: Saves the changes made.
Spindle’s Idle Load Calibration: Sets the idle load characteristics of the
Spindle to produce similar characteristics as that of the Spindle of
another Model 7100.
Figure 8-4: Control Screen