Recipe Parameters
Kerf Check Parameters
Advanced Dicing Technologies Ltd.
A-36
Kerf Check Last Cut No.
The Street where Kerf Checking ends.
Possible Values:
min = 1, max = 999, Default = 999
The default value of 999 means Kerf Checking is
performed to the last cut.
Kerf Check
Max. Failures per
Cut
The number of Kerf Check failures permitted per cut.
If more than this number of Kerf Checks fail, the
Recover option comes into play.
Possible Values:
min = 0, max = 99, Default = 10
Kerf Check
No. Checks per
Cut
The number of Kerf Checks performed on each cut.
Possible Values:
min = 0, max = 99, Default = 5
Kerf Check
Number of Steps
per Check
Defines whether the Kerf Check will be performed in
one step or in two steps. When set to 2, all Kerf Check
parameters have two lines in the parameter table (see
Figure 6-33)
Possible Values: 1-2
Default value: 1
Kerf Check
Perform Y-Offset
in Step
Defines the Kerf Check step, in which the Y-Offset
procedure is performed.
Options: 1 (Default), 2
Kerf Check
Perform
Z-Compensation
in Step
Defines, according to which Kerf Check step the
System performs Z-Compensation.
Options: 1, 2 (Default)
Kerf Check Rate
The number of Streets cut before a Kerf Check is
performed.
Possible Values:
min = 0, max = 999, Default = 5
Kerf Check Recover Option
The action taken by the Model 7100 should the Kerf
Check fail.
Possible Values:
Pause (default): Machine stops and waits for User
intervention, for example, for the user to find a Model.
Report: Failure reported, machine continues cutting.
Ignore: Failure ignored, machine continues cutting.
Table A-16: Kerf Check Parameters