ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Manual Inspection Illumination
P/N 97100-9002-000-14 Ver 06/05
8.7-1
8.7 Manual Inspection Illumination
To provide the best illumination for manual workpiece inspection, the user
can pre-set the illumination parameters in the Manual Inspection
category:
Coaxial Illumination After Cut - Defines the Coaxial illumination
intensity for the inspection that is done after the cut.
Oblique Illumination After Cut - Defines the Oblique illumination
intensity for the inspection that is done after the cut.
Inspection Focus Type Before Cut - Defines the Z position for the
inspection that is done before the cut.
Coaxial Illumination Before Cut - Defines the Coaxial illumination
intensity for the inspection that is done before the cut. (This parameter
is inserted manually).
Oblique Illumination Before Cut - Defines the Oblique
illumination intensity for the inspection that is done before the cut.
(This parameter is inserted manually).
The value for each parameter is the light intensity the saw will use during
Manual Inspection. The values can be taught at any point during process.
To Teach the Manual Inspection Illumination
1 Pause the saw. The system switches to Inspection mode.
2 Set the best illumination for inspection.
3 Insert the Before Cut parameters, if required.
4 Right click in the main video screen and select "set illumination".
For more information, refer to Table A-21 in Manual Inspection
Parameters.
Note: The Yes/No parameter "Inspection before Cut" allows performing
inspection on the street prior to the cut.