ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Kerf Checking
P/N 97100-9002-000-14 Ver 06/05
6.3-7
Double-clicking on the Model displays a close-up of the Kerf in the
Multiview of the FOV, which may help the User to understand why a Kerf
Check failed.
6.3.5 Manual Kerf Check
Although the Model 7100 automatically performs Kerf Checking according
to the Kerf Check algorithm specified in the Recipe, once Kerf Check has
been taught, Manual Kerf Checking can be performed at any time. For
more information on Teaching Kerf Check, see
section 6.3.6.
To Perform Manual Kerf Check:
1 Click in the toolbar. The Wizard in the Video Workspace guides
the User through each step of the procedure.
2 Click Finish.
6.3.5.1 Manual Cut Depth Compensation
This of Manual Kerf Check is applicable for systems that use Bevel-type
blades. The option allows the user to manually adjust the Kerf Check using
calculations or by visual confirmation. The Manual Kerf Check option can
Note: The Model tab is described in detail in Chapter 2.