7.
The scanner should now be responding to the input waveform, but should look very
underdamped. Continue to turn R28 CW until the oscillations just die out before the next half
cycle ofthe input signal. See figure 19.
8. Turn R25 CW to minimize the first overshoot and to minimize the oscillations. See figure 20.
HfD 20omV
%
(inz 200mV ^M 5msfext/io/ 1.58V 'HB '2fl6mV
^^
Chi mmV KfA 5msExt/ld/ 1.58V
Figure 19.
Figure 20.
9. Tum R59 CW until the undershoot is minimized, i.e. at the same amplitude as the settled
position. See Figure 21.
10.
Tum R25 CW until the first overshoot is minimized, i.e. at the same amplitude as the settled
position. See Figure 22.
43