Notes:
Character Set
Conversion
A common problem in a multiple host environment is that
different hosts use different ASCII character sets. As a result of
this, language specific characters (such as å ü ô ñ) are sometimes
printed incorrectly.
The AXIS 5900 solution to this problem is to assign a character
set conversion filter to a logical printer, and then link that
logical printer to the host causing the problem.
You select your desired conversion filter by setting the
Character Set Conversion (PRx_CSET) parameter. The output
from the conversion filter is always IBM PC Set 2 (Code Page
437), and this is the character set the printer must be set up for.
Example:
Follow the instructions below to change the conversion filter:
1. From the print server’s internal web page, select Admin | Logical
Printer Settings.
2. Select the PR1 tab.
• The examples in this section describe how you can configure the available
logical printers using a standard web browser. If you want to set them directly
by editing the config file, just enter the values for the corresponding
parameters.
• The examples should only be viewed as suggestions how to configure the
logical printers. You should, off course, configure them according to the needs
of your network.
• In the Parameter List, on page 138, you can find a complete list of the AXIS
5900 parameters.
• Refer to Section 10 Management and Configuration, on page 92, for more
information about the available management tools.
Your network contains a host using the character set ISO 8859-2 and a host
using the character set DEC. In order to direct their print jobs to the printer
connected to the AXIS 5900, you should assign each host to a separate logical
printer, and install a character set conversion filter.