Axis AXIS USB Bedienerhandbuch Seite 36

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 35
32 HyTechWorks©2013 – V3.1
Homing/Soft Limits
The homing process is divided into 2 stages. The first stage is to seek the home
switch with speed of G0 speeds predefined percentage (plugin configs Home
Speed%”) according to pre-defined direction. When the home switch is triggered,
the moving speed is decelerated to 0 and the second stage starts. The second
stage is to leave the home switch with the speed of predefined % of the first
stage speed towards the opposite direction. The home position is the spot where
the home switch changes its state again. HyCNC-4P will set its internal coordinate
counter according to the defined home switch offset. Then moving speed is
decelerated to 0. The order of the homing is also defined. Operate the main
Seitenansicht 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 67 68

Kommentare zu diesen Handbüchern

Keine Kommentare