MOUNTING TEMPLATE
2
1
ENGLISH
3
4
INSTALLATION
1. Affix the mounting template at the desired mounting position.
2. Drill two mounting holes of ø3.4mm (ø1/8”).
3. To pass the cable through to the header, drill a wiring hole of ø8mm (ø5/16”).
4. Remove the mounting template.
5. Remove the housing cover. Attach the sensor to the mounting surface with two mounting screws.
The sensor mounting position may be limited depending on the header thickness and the mounting height.
NOTE
CAUTION
Risk of getting caught.
Make sure to affix the mounting template as described in the above chart.
Otherwise, it can be dangerous since there may be no presence detection area
around the threshold. Install the sensor as low as possible on the header.
1.Plug the connector of the sensor.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches. (See ADJUSTMENTS)
Place the housing cover .
If wiring is to be exposed, break the knockout.
WARNING
Danger of electric shock.
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain-cover
(Separetely available) otherwise electric shock or breakdown of
the sensor may occur.
MANUFACTURER'S STATEMENT
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of equipments.
Danger of electric shock.
WARNING
CAUTION
NOTE
Disregard of warning may cause the improper operation causing death or serious injury of
person.
Special attention is required to the section of this symbol.
Disregard of caution may cause the improper
operation
causing injury of person or damage to
objects.
NOTE
Read this operation manual carefully before use to ensure proper operation of the sensor.
Failure to read this operation manual may cause improper sensor operation and may result in serious injury or death of
person.The meanings of the symbols are as follows. Please study the following first and then read the contents of this
operation manual.
1. This sensor is a non-contact switch intended for header mount / wall mount of an automatic door.
Do not use for any other applications. This sensor cannot be used for industrial doors or shutters,
when used, proper operation and safety cannot be guaranteed.
2. When setting the sensor's detection area, make sure there is no traffic around the installation site.
3. Before turning the power on, check the wiring to prevent damage or malfunction of equipments that are connected
to the sensor.
4. Only use the sensor as specified in the operation manual provided.
5. Be sure to install the sensor in accordance with the local laws and standards of the country in which the sensor is
installed.
6. Before leaving the job site make sure that the sensor is operating properly and instruct the building owner/operator
on proper operation of the door and the sensor.
7.The sensor setting can only be changed by an installer or service engineer. When changed, register the changed
 setting and dates in the maintenance logbook accompanying the door.
The following conditions are not suitable for the sensor installation.
-Fog or exhaust emission around the door.
-Wet floor
-Vibrating header or mounting surface.
-Moving objects or a heating radiator in the detection area.
-Highly reflecting floor or the presence of highly reflecting objects around the door.
.
NOTE
H: Height from the floor to the bottom of the header
Y:
Distance between the bottom of header and the sensor.
X: Distance between the door and the mounting surface
X
H
Y
Sensor
Door
Header
Floor
Maximum mounting distance (Y)
[mm(feet,inch)]
WARNING
Before starting the procedure, ensure that the power is turned OFF.
When passing through the cable to the hole, make sure not to tear the shield,
otherwise it may cause electric shock or breakdown of the sensor.
Danger of electric shock.
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
To enable the presence detection, do not enter the detection area for 10 seconds after supplying the power.
SPECIFICATIONS
Model
Cover color
Mounting height
Detection area
Detection method
Depth angle adjustment
Power supply
Power consumption
Operation LED
: OA-AXIS I / OA-AXIS II
: Silver / Black
: 2.0 (6'7") to 3.5m (11'5")
: See DETECTION AREA
: Active Infrared Reflection
: 1st to 3rd rows / -6 to +6
4th and 5th rows / +26 to +44
: 12 to 24VAC( 10%)
12 to 30VDC( 10%)
: OA-AXIS I < 3VA
OA-AXIS II < 4VA
: Green / Stand-by
Blinking Red / 1st row detection
Red / 2nd row detection
Orange / 3rd to 5th rows detection
Output
Output hold time
Response time
Operating temperature
IP rate
Weight
Accessories
: OA-AXIS I /
Form C relay
50V 0.3A Max.(Resistance load)
OA-AXIS II /
  1st to 3rd rows / Form C relay
50V 0.3A Max. (Resistance load)
3rd to 5th rows / Form C relay
50V 0.3A Max.(Resistance load)
: Approx. 0.5 sec.
: <0.3 sec.
: -20 to +55 C(-4 to 131 F)
: IP44
: 320g (11.2oz)
: 1 Cable 3m (9'10")
1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
The specifications herein are subject to change without prior notice due to improvements.
NOTE
OUTER DIMENSIONS AND PART NAMES
62.3(2 7/16")
267(10 1/2")
45(1 3/4")
7.5(5/16")
-6°
26°
44°
Snow
Mode
Immunity
PRESENCE
ON
OFF
ON
OFF
ACTIVATION
Narrow
Shallow Deep
10
9
1,2
Low
Middle
High
S-High
Sensitivity
3,4
15sec.
60sec.
180sec.
Presence
Timer
5,6
B
C
D
A
Frequency
7,8
Row
Adjustment
5 rows
4 rows
3 rows
2 rows
Depth
6°
-6°
44°
26°
Depth
Width
RL
Width
RL
Not applicable
35°
-3°
39.5°30.5°
5730350
1 2 3 4 6 7 8 9 10 11 12 14 15 16135
Wide
Narrow
Wide
Installation
Mode
ON
OFF
16
(1)
(5)
(4)
(6) (7)
(3)
125(4 15/16")
36(1 7/16")
43(1 11/16")
(2)
(8)
(1) Connector
(2) Mounting holes
(3) Operation LED
(4) Depth angle adjustment screw
(5) Width adjustment screws
(6) Dipswitches
(7) Detection window
(8) Area adjustment tool
[mm (inch)]
DETECTION AREA
The actual detection area may become smaller depending on the ambient light, the color / material of the
object or the floor as well as the entry speed of the object.
NOTE
OA-AXIS I
OA-AXIS II
}
Grey
Grey
White
Yellow
Green
Power supply
12 to 24VAC 10
12 to 30VDC 10%
Common (COM.)
Normally open (N.O.)
Normally closed (N.C.)
}
Grey
Grey
White
Yellow
Green
Common (COM.)
Normally open (N.O.)
Normally closed (N.C.)
White Str.
Yellow Str.
Green Str.
Common (COM.)
Normally open (N.O.)
Normally closed (N.C.)
Power supply
3rd to 5th
rows output
1st to 3rd
rows output
*
*
Wire the cable to the door controller properly as shown in the drawing below.
12 to 24VAC 10
12 to 30VDC 10%
[m(feet,inch)]
A
B
C
D
E
2.20(7'2 5/8")
0.14(5 1/2")
0.42(1'4 9/16")
0.82(2'8 5/16")
1.35(4'5 1/8")
1.90(6'2 13/16")
2.50(8'2 7/16")
0.16(6 5/16")
0.48(1'6 7/8")
0.93(3' 5/8")
1.54(5' 5/8")
2.17(7'1 7/16")
F
G
1.33(4'4 3/8")
2.05(6'8 11/16")
1.51(4'11 7/16")
2.32(7'7 5/16")
H
2.78(9'1 7/16")
3.15(10'4")
2.70(8'10 5/16")
0.18(7 1/16")
0.52(1'8 1/8")
1.00(3'3 3/8")
1.66(5'5 3/8")
2.34(7'8 1/8")
3.00(9'10 1/8")
0.20(7 7/8")
0.58(1'10 13/16")
1.10(3'7 5/16")
1.85(6' 13/16")
2.60(8'6 3/8")
1.63(5'4 3/16")
2.51(8'2 13/16")
1.81(5'11 1/4")
2.79(9'1 13/16")
3.40(11'1 7/8") 3.79(12'5 3/16")
3.50(11'5 13/16")
0.23(9 1/16")
0.67(2'2 3/8")
1.30(4'3 3/16")
2.16(7'1 1/16")
3.03(9'11 5/16")
2.11(6'11 1/16")
3.26(10'8 3/8")
4.42(14'6")
I
OA-AXIS I / II
5915031 JAN 2009
*The outputs from the 3rd row overlaps.
1st row
2nd row
3rd row
4th row
5th row
: Emitting spots
: Detection area
A
B
C
D
E
F
GG
H
I
Sensor setting
1st to 3rd rows : +6
4th and 5th rows : +44
Motion / Presence
detection
Motion detection
: Emitting spots
(Can be elminated)
*The values of the chart above is of the emitting spots, but not of the detection area.
X
2,000 (6' 6") 2,200 (7' 2") 2,500 (8' 2") 3,000 (9' 10")
0
No limit
50 (1 15/16") 200 (7 7/8") 200 (7 7/8") 200 (7 7/8")
100 (3 15/16") 200 (7 7/8") 200 (7 7/8") 200 (7 7/8") 200 (7 7/8")
150 (5 7/8") 130 (5 1/8”) 150 (5 7/8”) 170 (6 11/16") 200 (7 7/8")
200 (7 7/8")
- 110 (4 5/16”) 130 (5 1/8”) 150 (5 7/8”)
250 (9 13/16") 120 (4 3/4”)
300 (11 13/16") - -
H
200 (7 7/8")
-
- -
- -
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - OA-AXIS I / II

MOUNTING TEMPLATE21ENGLISH34INSTALLATION1. Affix the mounting template at the desired mounting position.2. Drill two mounting holes of ø3.4mm (ø1/8”).

Seite 2 - Front view

1ADJUSTMENTS2Make sure the detection area does not overlap with the door / header,otherwise ghosting / signal saturationmay occur.Do not place any hig

Seite 3 - OA-AXIS T

45(1 3/4")63(2 1/2")267(10 1/2")125(4 15/16") 36(1 7/16") 43(1 11/16") 7(1/4")1st to 3rd rows4th and 5th rowsNarro

Seite 4 - East Coast Office

Mounting height [ m (feet,inch) ]2.0 (6' 6") 2.2 (7' 2") 2.5 (8' 2") 3.0 (9' 10")Contact your installer or ser

Kommentare zu diesen Handbüchern

Keine Kommentare