LNC-M8000
Function
寶元數控精密股份有限公司 201
LNC Technology Co., Ltd.
ALARM(PATH,ALARM_No)
Command system MACRO to send
Alarm
W
Description
This function is only for system MACRO to use
PATH =>path numberValue range 0 ~6, unitN/A
0Current path1~6First path~6th path.
ALARM_No =>Appoint alarm number(1~511)Value range1 ~ 511, unitN/A
Reply
N/A
Example
ALARM(0,1); /* send alarm 610001 */
TAN_FOLLOW(PATH,TYPE,VALUE)
Tan-follow Function Setting
W
Description
PATH =>Path No., value range0 ~6, unitN/A
0Current path, 1~6First path~6th path.
TYPE =>Setting item, value range****, unitN/A
1: Tan-follow function setting axis(0:N/A,1~3:Cartesian coordinate previous 3 axis), unit
N/A
2: Tan-follow direction(0:+,1:-), unitN/A
VALUE =>Write info, value range0 ~ 2147483647, unitN/A
Reply
Alarm
-1 => Direction is over range
Example
TAN_FOLLOW(0,1,3); /* Tan-follow function setting=3
rd
axis */
8.4 Read/write system info function
R_G_GROUP(PATH,GROUP)
Read G code group
R
Description
PATH =>Path No., value range 0 ~6, unitN/A.
0Current path, 1~6First path~6th path.
GROUP =>G group[0~22], value range0~22, unitN/A
Reply
Part program read G code group, unitN/A
Alarm
-1 => Group No. is ove range
Example
#1= R_G_GROUP(0,1); /* If current group 1=G2, #1Value=2 */
R_SYS_INFO(PATH,TYPE)
Read system info
R
Description
PATH =>Path No., value range 0 ~6, unitN/A.
0Current path, 1~6First path~6th path.
TYPE =>Type, value range****, unitN/A.