AXISA1001NetworkDoorController&AXISEntryManager
SystemConguration
Todeleteandrecongurethehardwareconguration,clickResetandstartnewhardwareconguration.
Locks
1.Ifadoormonitorwillbeused,selectDoormonitorandthenselecttheoptionthatmatcheshowthedoormonitor
circuitswillbeconnected.
2.Ifthedoorlockshalllockimmediatelyafterthedoorhasbeenopened,selectLockwhendooropens.
3.Specifythedoormonitortimeoptions,orifnodoormonitorwillbeused,thelocktimeoptions.
Thefollowingoptionsfordoormonitors,doormonitortimeandlocktimeareavailable:
•Doormonitor
-Opencircuit=Opendoor–Thedoormonitorgivesthedooropensignalwhenthecircuitisopen.Selectifthe
doormonitorcircuitisnormallyclosed.
-Opencircuit=Closeddoor–Thedoormonitorgivesthedoorclosedsignalwhenthecircuitisopen.Selectif
thedoormonitorcircuitisnormallyopen.
•Lockwhendooropens–Selectifthedoorshalllockimmediatelyafterthedoorhasbeenopened.Whenthedoor
closes,thedoorlockswithoutdelay.
•Accesstime–Setthenumberofsecondsthedoorshallremainunlockedafteraccesshasbeengranted.Thedoorremains
unlockeduntilthedoorhasbeenopenedandwilllockwhenitclosesregardlessofwhethertheaccesstimehasexpiredor
not.Ifthedoorremainsunopened,itlockswhenthesetaccesstimehasbeenreached.
•Opentoolongtime–Setthenumberofsecondsthedoorisallowedtostayopen.Ifthedoorisstillopenwhenthe
opentoolongtimehasbeenreached,thedooropentoolongalarmistriggered.Setupanactionruletocongurewhich
actiontheopentoolongeventshalltrigger.
•Pre-alarmtime–Apre-alarmisawarningsignalthatistriggeredbeforetheopentoolongtimehasbeenreached.It
tellstheadministratorand,dependingonhowtheactionrulehasbeensetup,itcanalsowarntheuser(theperson
enteringthedoor)thatthedoorneedstobeclosedortherealalarm,thedooropentoolongalarm,willgooff.Setthe
numberofsecondsbeforethedooropentoolongalarmistriggeredthesystemshallgivethepre-alarmwarningsignal.
Todisablethepre-alarm,setthepre-alarmtimeto0.
•Doorunlockedtime–DeselectDoormonitortomakethisoptionavailable.Setthenumberofsecondsthedoorshall
remainunlockedafteraccesshasbeengranted.Thedoorremainsunlockeduntilthedoorhasbeenopenedandwill
lockwhenitclosesregardlessofwhetherthedoorunlockedtimehasexpiredornot.Ifthedoorremainsunopened,it
lockswhenthesetdoorunlocktimehasbeenreached.
•Pre-locksignaltime–DeselectDoormonitortomakethisoptionavailable.Apre-locksignalisawarningsignalthatis
triggeredbeforethedoorlocks.Ittellstheadministratorand,dependingonhowtheactionrulehasbeensetup,itcanalso
warntheuser(thepersonenteringthedoor)thatthedoorwilllocksoon.Setthenumberofsecondsbeforethedoor
locksthesystemshallgivethepre-lockwarningsignal.Thepre-locksignaltimemustbeshorterthanthedoorunlocked
time.Todisablethepre-lockwarningsignal,setthepre-locksignaltimeto0.
Forinformationabouthowtosetupanactionrule,seeSettingUpanActionRule,onpage29.
Thefollowingoptionsforlocksareavailable:
•12V
-Locked=GND(-)–Selectforlocksthatremainlockedduringpoweroutages(failclose/secure).
-Locked=12V–Selectforlocksthatunlockduringpoweroutages(failopen/safe).
•Relay–Canonlybeusedononelockperdoorcontroller.Iftwodoorsareconnectedtothedoorcontroller,arelaycan
onlybeusedonthelockoftheseconddoor.
-Locked=Relayopen–Selectforlocksthatremainlockedwhentherelayisopen(failclose/secure).