AXIS 247S - System Options
28
SNMP
The Simple Network Management Protocol (SNMP) allows the remote management of network devices. Select
the version of SNMP to use, depending on the level of security required. Select the version of SNMP to use, by
checking the appropriate box. The three levels of security are:
SNMP V1 - includes no security
SNMP V2c - uses very simple security, e.g. community name as password
SNMP V3 - provides encryption and secure passwords. Use with HTTPS.
If using V1 and V2c, enter the community name for read-only access to all supported SNMP objects (except
the root password and other objects that require write access). Default value = public. You can also specify the
community name for read/write access to all supported SNMP objects (except read-only objects).
Default value = pass.
If using HTTPS enter the password if it has not already been set. To set the password again, the Video Server
must be reset to the factory default settings.
UPnP™
The Video Server includes support for UPnP in Windows ME and Windows XP. UPnP is enabled by default.
Note: UPnP™ must be installed on your workstation if running Windows XP. To do this, open the Control Panel from the Start Menu and
select Add/Remove Programs. Select Add/Remove Windows Components and open the Networking Services section. Click Details
and then select UPnP™ as the service to add.
RTP (Multicast)/MPEG-4
These settings are the IP address, port number, and Time-To-Live value to use for the media stream(s) in
multicast MPEG-4 format. Only certain IP addresses and port numbers should be used for multicast streams.
For more information, please see the online help.
Bonjour
When Bonjour is enabled, the video server is automatically detected by operating systems and clients that
support this protocol.
Ports & Devices
I/O Ports - the pinout, interface support and the control and monitoring functions provided by this connector
are described in
Unit Connectors, on page 31.
Maintenance
Restart - The unit is restarted without changing any of the settings. Use this method if the unit is not
behaving as expected.
•Restore - The unit is restarted and most current settings are reset to factory default values. The set-
tings that will not be reset are as follows:
the boot protocol (DHCP or static)
the static IP address
the default router
•the subnet mask
the system time
Default - The default button should be used with caution. Pressing this will return all of the Video
Server's settings to the factory default values (including the IP address)
Upgrade Server - See Upgrading the Firmware, on page 33.
Backup - To take a backup of all of the parameters, and any user-defined scripts, click this button. If necessary,
it is then possible to return to a previous configuration if settings are changed and there is unexpected