AXISA1001NetworkDoorController
ControlButton
Thecontrolbuttonisusedfor:
•Resettingtheproducttofactorydefaultsettings.Seepage35.
•ConnectingtoanAXISVideoHostingSystemserviceorAXISInternetDynamicDNS
Service.Formoreinformationabouttheseservices,seetheUserManual.
Specications
OperatingConditions
TheAxisproductisintendedforindooruse.
Classication
TemperatureHumidity
IEC60721-4-3Class3K3,
3M3
0°Cto50°C
(32°Fto122°F)
20–85%RH(non-condensing)
PowerConsumption
NOTICE NOTICE
NOTICE
UseaSafetyExtraLowVoltage(SELV)compliantlimitedpowersource(LPS)witheithera
ratedoutputpowerlimitedto≤100Woraratedoutputcurrentlimitedto≤5A.
PowersupplyMaximumloadonoutputs
PoweroverEthernetIEEE802.3af/802.3atType1Class3
7.5W
10–30VDC,max26W
14W
WireArea
NOTICE NOTICE
NOTICE
EachwireshallhaveanareathatcorrespondstoAWG28–16(CSA)orAWG30–14(CUL/UL).
Selectcablesincompliancewithyourlocalregulations.
AWG
Diametermm(in)
Areamm
2
28–16
0.321–1.29(0.0126–0.0508)
0.0810–1.31
30–14
0.255–1.63(0.01–0.0641)
0.0509–2.08
16
Kommentare zu diesen Handbüchern