AXIS 282/282A Installation Guide Page 3
The Terminal I/O Connector
The AXIS 282/282A provides one 4-pin terminal I/O connector.
Note: Pins 3 and 4 in the Terminal I/O Connector are the same Alarm In and Alarm Out as pins 8 and 9 in
the 34-Pin Header.
If the AXIS 282/282A has been configured to have power going in
through the 34 I/O pins, power can be configured to go out through pin 1
of the Terminal I/O Connector.
Schematic Diagram - Terminal I/O Connector
Network connector
The AXIS 282/282A connects to the network via a standard STP network
cable, and automatically detects the speed of the local network segment
(Ethernet 10BaseT/100BaseTX, RJ-45).
Pin Function
1 Power in/out (8 - 20V)
2GND
3Alarm In
4Alarm Out
123 4