6
AXIS 240Q Blade - Rack Solution Installation Guide
The I/O Terminal Block
The AXIS 240Q Blade Video Server connects to an I/O terminal block used for transmitting
data over multi-drop communication lines:
• RS-485 Pan/Tilt devices
• RS-232 Pan/Tilt devices
• External triggering (typically associated with CCTV equipment)
The AXIS 240Q Blade supports several Pan/Tilt device drivers, which are available from
the Axis Web site at www.axis.com
Connector Pinout
The pinout for the I/O Terminal Block and the signaling details for each pin:
For compatible replacement connectors, contact http://www.phoenixcontact.com, quoting:
MC1.5/14-ST-3.81 (art. no. 1803691).
For further information, please refer to the Unit Connections section in the AXIS 240Q
User’s Manual.
Pin Function Description Pin Function Description
1 RS-232 RI 15 RS-485 - A
(non-inverting)
A half-duplex RS-485 interface for con-
trolling auxiliary equipment, e.g. PTZ
devices.
2 RS-232 CTS 16 RS-485 - B
(inverting)
3 RS-232 RTS 17 Transistor Output 4 With a maximum load of 100mA and
maximum voltage of 24V DC, this out-
put has an open-collector NPN transis-
tor with the emitter connected to GND.
To use with an external relay, a diode
must be connected in parallel with the
load, for protection against voltage
transients.
4 RS-232 DSR 18 GND
5 GND 19 Transistor Output 3 See Transistor Output 4 above.
6 RS-232 DTR 20 Transistor Output 2 See Transistor Output 4 above.
7 RS-232 TXD 21 GND
8 RS-232 RXD 22 Transistor Output 1 See Transistor Output 4 above.
9 RS-232 CD 23 Digital Input 4 Connect to GND to activate, or leave
floating (or unconnected) to deactivate
10 GND 24 GND
11 n/a 25 Digital Input 3 See Digital Input 4 above.
12 n/a 26 Digital Input 2 See Digital Input 4 above.
13 n/a 27 GND
14 n/a 28 Digital Input 1 See Digital Input 4 above.